Location: Hodgkin & Huxley (1952) model @ ee1217d73e4f / components / temperature_factor.cellml

Author:
WeiweiAi <wai484@aucklanduni.ac.nz>
Date:
2021-04-27 16:19:31+12:00
Desc:
Change the temperature T to 18.5 as stated in the paper.
Permanent Source URI:
https://staging.physiomeproject.org/workspace/64f/rawfile/ee1217d73e4f181e7509248a19c5f4ea8d7ed3b3/components/temperature_factor.cellml

<?xml version='1.0' encoding='UTF-8'?>
<model name="temperature_factor" xmlns="http://www.cellml.org/cellml/1.1#" xmlns:cellml="http://www.cellml.org/cellml/1.1#">
    <!-- calculate temperature factor-->
    <component name="temperature_factor">
        <variable name="phi" public_interface="out" units="dimensionless"/>
        <variable name="T" public_interface="in" units="celsius"/>
        <math xmlns="http://www.w3.org/1998/Math/MathML">
            <apply>
                <eq/>
                <ci>phi</ci>
                <apply>
                    <power/>
                    <cn cellml:units="dimensionless">3</cn>
                    <apply>
                        <divide/>
                        <apply>
                            <minus/>
                            <ci>T</ci>
                            <cn cellml:units="celsius">6.3</cn>
                        </apply>
                        <cn cellml:units="celsius">10</cn>
                    </apply>
                </apply>
            </apply>
        </math>
    </component>
</model>