- Author:
- Shelley Fong <sfon036@UoA.auckland.ac.nz>
- Date:
- 2025-08-14 14:47:50+12:00
- Desc:
- add pics. Rename gating to activation
- Permanent Source URI:
- https://staging.physiomeproject.org/workspace/d57/rawfile/32386e6d968ffd6099ef50267e3d7fde9d67dde4/parameter_finder/kinetic_parameters_K1_uterine.py
# K1 module from Tong 2011
# Return kinetic parameters, constraints, and vector of volumes in each
# compartment (pL) (1 if gating variable, or in element corresponding to
# kappa)
# Translated from Pan 2018 cardiac AP
import numpy as np
def kinetic_parameters(M, include_type2_reactions, dims, V):
# Set the kinetic rate constants
num_cols = dims['num_cols']
num_rows = dims['num_rows']
# constants are stored in V
F = V['F']
N_A = V['N_A']
# from MATLAB PSO for the channel
G_GHK = 3.25970736700753e-11
# convert to permeability
P = G_GHK / F * 1e12 #Unit pL / s
channel_K1 = P
kf =[channel_K1]
kr =[channel_K1]
k_kinetic = kf + kr
# CONSTRAINTS
N_cT = []
K_C = []
# volume vector
# W = list(np.append([1] * num_cols, [V['V_myo']] * num_rows))
W = [1] * num_cols + [V['V_myo'], V['V_o']]
return (k_kinetic, N_cT, K_C, W)